4000 Media Gateway Series Reference Guide
Page 60
To configure the settings for each user that should register at the same registrar server, click Add and configure
the following parameters:
Logging and Diagnostics
You can configure the following parameters shown in Logging and Diagnostics section:
URI scheme: This option is only available if you selected TLS as Registrar protocol.
Calls are transmitted via various proxy servers. Some of them do not transmit the calls as
encrypted calls. If you select SIP (default), you allow calls to be transmitted via such proxy
servers.
To make sure that a call is sent encrypted to the proxy of the remote side, select SIPS (secure
SIP). If a call is routed via a proxy server that is not able to route the call encrypted, it rejects
the call and the call is send to another proxy until it can be transmitted.
Own display
name:
Enter the name that should be displayed at the registrar server.
URI scheme: Select either SIP (default) or SIPS as URI scheme.
User name: Enter the name or number that Diva SIPcontrol uses to register at the registrar server.
Domain: Enter the domain name of the registrar server.
Protocol: Select UDP if you register as an e-phone gateway.
Re-register time: Enter the re-register time in seconds. This is the time for which the registration to the registrar
server remains valid. After this time has elapsed, the SIP stack service would need to
re-register to be available again. The default value is 3600 seconds.
Auth user name: Enter a user name for authentication at the registrar server.
Password: Enter your password for authentication at the registrar server.
Register as: Leave the setting at the default value Standard. Select e-phone GW only if you use e-phone
and you want Diva SIPcontrol to function as a gateway for e-phone.
Event Log Level: A computer with Diva SIPcontrol installed can write different types of events into the System Event
Log. The details for each event log are described in Event
Logging on page 89.
Debug Level: The debug level setting can be used for debugging and tracing purposes. During normal operation,
it should be set to Off to lessen the effect on system performance.
XML
configuration
file:
Shows the configuration in raw format. This option is used only by Dialogic Support.