Dialogic DSI SS7MD Manual de usuario Pagina 99

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 98
99
Dialogic
®
DSI Signaling Server SGW Mode User Manual Issue 5
Syntax
MSLCP:[RESET=,];
Prerequisites
None.
Attributes
None.
Examples
MSLCP;
MSLCP:RESET=Y;
Output Format
Software License Capability Traffic Measurements
CAPABILITY RXDATA TXDATA RXPEAK TXPEAK PEAK CONG ENFORCE PERIOD
M3UA 4204E5 3212E4 154 456 923 1 1 01:33:33
EXECUTED
6.10.4 MSPCP – Measurements PCM Print
Synopsis
This command prints traffic measurements for PCMs. The measurements are cumulative between system
startup and the next time the measurements are reset.
The fields have the following meanings:
PCM - PCM on a board
FMSLIP - Frame Slip count
OUTSYN - Out-sync transitions
ERRSEC - Errored Seconds count
SEVSEC - Severely Errored seconds count
PERIOD - Time since measurements on the route were last reset. Specified in hours, minutes and
seconds
Syntax
MSC7P:[C7LINK=,][RESET=,];
Prerequisites
If specified, the PCM must be initiated and on an unblocked board.
Attributes
None
Examples
MSPCP:PCM=5-1;
MSPCP;
Output Format
PCM Traffic Measurements
PCM FMSLIP OUTSYN ERRSEC SEVSEC PERIOD
3-3 57 60 23 1 23:00:00
3-4 12 35 33 4 01:00:00
4-4 53 55 4 0 01:00:00
EXECUTED