Chapter 6 Command Definitions
6.5.1 CNBOI – Configuration Board Initiate
Synopsis
This command defines a new board on the system.
The user should specify the board position (BPOS) within the unit, the physical type of the board (BRDTYPE)
and the signaling type (SIGTYPE), which identifies the software that will run on the board.
See Section 7.1.2, “Boards and PCMs” on page 136 for a more detailed description of board configuration.
Syntax
CNBOI:BPOS=,BRDTYPE=,SIGTYPE=;
Prerequisites
No board has already been defined for the specified board position.
A board must physically exist for the board position and be licensed for the Signaling Gateway.
If you are using a Dialogic
®
DSI SS7HDP Network Interface Board, it must have a signaling type of SS7.
Attributes
CONFIG
Examples
CNBOI:BPOS=1,BRDTYPE=SPCI4-4-4,SIGTYPE=SS7;
CNBOI:BPOS=1,BRDTYPE=SPCI2S-4-2,SIGTYPE=SS7;
CNBOI:BPOS=3,BRDTYPE=SS7HDP-64-4,SIGTYPE=SS7;
6.5.2 CNBOE – Configuration Board End
Synopsis
This command deassigns a board from a board position.
Syntax
CNBOE:BPOS=;
Prerequisites
A board has been defined for the specified board position.
No signaling processor on the board has been allocated to a signaling link.
No PCM on the board is configured.
The board has been blocked.
Attributes
CONFIG
Examples
CNBOE:BPOS=3;