98
Chapter 6 Command Definitions
Syntax
MSEPP:[RESET=,][PAGE=,];
Prerequisites
None.
Attributes
None.
Examples
MSEPP:RESET=YES,PAGE=2;
MSEPP;
Output Format
Ethernet Port Measurements (Page 1 of 2)
ETH RXKBYTE RXPKT RXERR RXDROP TXKBYTE TXPKT TXERR TXDROP PERIOD
1 0 0 0 0 0 0 0 0 16:34:41
2 96324 135705 0 4204E5 28169 4444 0 0 16:34:41
3 0 0 0 0 0 0 0 0 16:34:41
4 3760 3273 0 33615 12503 3455 0 0 16:34:41
EXECUTED
Ethernet Port Measurements (Page 2 of 2)
ETH RXFIFO RXFRAME RXCOMP RXMULT TXFIFO TXCOLLS TXCARRIER TXCOMP PERIOD
1 0 0 0 0 0 0 0 0 16:34:41
2 0 0 0 0 0 0 0 0 16:34:41
3 0 0 0 0 0 0 0 0 16:34:41
4 0 0 0 0 0 0 0 0 16:34:41
EXECUTED
6.10.3 MSLCP – Measurement of License Capability Print
Synopsis
This command prints the traffic measurements for each license on the system capable of supporting
throughput licensing.
The meaning of each field in the output is as follows:
• CAPABILITY - A licensable capability of the system. This may be a protocol license or an operating
mode license. A capability may have been purchased as a software license, shipped as part of the system
or bundled as part of another license. If a capability is either not active on the system or doesn't provide
measurements then it will not be displayed.
• RXDATA - The amount of data received in Kilobytes during the measurement period.
• TXDATA - The amount of data transmitted in Kilobytes during the measurement period.
• RXPEAK - The peak received data rate in Kilobytes/s averaged over a rolling thirty second time window.
• TXPEAK - The peak transmit data rate in Kilobytes/s averaged over a rolling thirty second time window.
• PEAK - The peak data rate for both transmitted and received data in Kilobytes/s averaged over a rolling
thirty second time window
• CONGESTION - The number of times the license has exceeded its throughput threshold.
• ENFORCEMENT - The number of times the unit has enforced the license throughput limit.
• PERIOD - Time since measurements on the route were last reset. Specified in hours, minutes and
seconds.
Note: Values are reset using the RESET parameter. MSEPP:RESET=Y; resets the measurement values
to 0.