Dialogic® Diva® SIPcontrol™ Configuration
45
Use session
timer:
Activates session monitoring via SIP session timers using the time-out
values given here. Refer to RFC 4028 for details.
Interval:
If Use session timer is enabled, you can set a time-out in seconds
until a call is considered to be aborted. Refreshes are normally
performed after the first half of the interval has elapsed. The minimum
value is 90 seconds. The default value is 600 seconds.
Minimum
session
expires:
If Use session timer is enabled, you can set a time in seconds
between two session refresh messages that Diva SIPcontrol will accept.
The minimum value is 90 seconds.
Address Normalization
You can configure the following parameters in the Address Normalization section when
you define or modify a SIP Peer:
Dialplan:
Select the local dialplan to be used by the dialplan module of Diva
SIPcontrol. Configure the local dialplan as described in Dialplans,
before you select it here.
The dialplan selected here applies only to outgoing calls.
Number
format
(outbound):
This parameter determines the shortest format allowed that is sent in
calls to this SIP peer. You can modify this parameter only if you
selected a dialplan from the drop down menu. The following options
are available:
Unchanged: The number signaled in the SIP message will be used
unchanged for dialing.
International number: The number is always converted to an
international number, including country and area code.
National number: The number is converted to a national number
unless it is an international number with a different country code.
Extension: The number is reduced as much as possible. An internal
number is reduced to its extension only.
For more information about number formats, see Number Modification
Using Address Maps.