Dialogic SS7G2X Manual de usuario Pagina 129

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 170
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 128
129
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
CCS SS7 Signalling Link Status (Page 2 of 2)
C7LINK L2 STATE L3 STATE L3 BLOCKING STATUS
1 BLOCKED ---- ---- ---- ---- ---- ---- ----
2 IN SERVICE AVAILABLE ---- ---- ---- ---- ---- LIIP ----
3 INITIAL ALIGN UNAVAILABLE ---- ---- ---- ---- ---- ---- ----
4 OUT OF SERVICE DEACTIVATED ---- ---- ---- ---- ---- ---- ----
EXECUTED
6.14.6 STEPP – Status Ethernet Port Print
Synopsis
This command provides the status of Ethernet ports on the system. The parameters output are:
ETH - The Ethernet port identity.
PARTNER - Identifies the other port member of a port bonding team.
SPEED - The speed of the Ethernet port (10 / 100 / 1000).
DUPLEX - Whether the port is FULL or HALF Duplex.
STATUS - Whether the port is UP or DOWN. If the port is in a team, and it is “up”, the status indicates
instead whether the port is ACTIVE or in STANDBY.
Syntax
STEPP;
Prerequisites
None
Attributes
None
Examples
STEPP;
Output Format
ETH PARTNER SPEED DUPLEX STATUS
1 DOWN
2 100 FULL UP
3 4 1000 FULL ACTIVE
4 3 1000 FULL STANDBY
EXECUTED
Vista de pagina 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 169 170

Comentarios a estos manuales