Dialogic SS7G2X Manual de usuario Pagina 96

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 170
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 95
96
Chapter 6 Command Definitions
6.10.5 MSSYP – Measurements System Print
Synopsis
This command prints out system related measurements for load and congestion taken over a period of time.
The fields in the output have the following meanings:
NOVLD - The number of periods of congestion (overload) during the measurement period.
MAXLOAD - Maximum load average measurement taken over one minute (based on the UNIX load
average).
LOADAVG - The average load on the system (based on the UNIX load average) measurement taken over
the measurement period.
PERIOD - The period the measurement was taken over.
Note: Values are reset using the RESET parameter. MSSYP:RESET=Y; resets the measurement values
to 0.
Syntax
MSSYP:[RESET=,];
Prerequisites
None
Attributes
None
Examples
MSSYP;
Output Format
System Measurements
NOVLD 0
MAXLOAD 28.81%
LOADAVG 2.28%
PERIOD 18:36:55
EXECUTED
Vista de pagina 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 169 170

Comentarios a estos manuales

Sin comentarios