65
Configuration Parameters
for BRI Ports
connect request before advancing an incoming call to the connected state.
Default value: FALSE
Configuration
Parameters for E1 ISDN
Ports
call_type
Specifies the call type to use when making the outbound call. Use one of the following
values for this field:
AUTO = Makes a call using the modem type and then automatically retries the call
using the voice type if the other end cannot accept modem calls.
MODEM = Makes a modem (3.1 kHz audio) call. This setting provides higher
quality audio for the call.
SPEECH = Makes a voice call.
Default value: AUTO
crc
Specifies a Boolean value that indicates whether the port has cyclical redundancy
checking (CRC) enabled. Set the parameter as follows:
FALSE = Indicates that the port has disabled CRC
TRUE = Indicates that the port has CRC enabled
Default value: TRUE
default_caller_id
Specifies a string of up to 15 characters that provides the caller ID to use when placing
outbound calls. If the user application provides a caller ID when placing a call, the system
ignores this field.
Unit: character string
Range: 1 - 15 (_ECC_MAX_ANI_LENGTH)
Default value: Blank
did_offset
Specifies a value that defines the number of digits to remove from the beginning of the
string of DID digits received from the network. Valid values are:
0 = Does not remove any DID digits
1 - 63 = Specifies the number of digits to remove
Range: 0 through 63
Default value: 0
did_timeout
Specifies a value that defines the maximum timeout allowed before processing the call
after assuming receipt of the last DID digit. Valid values are:
0 = Indicates no waiting time
1 - 20 = Specifies the number of seconds to allow after receiving the last DID digit
before processing the call
Unit: second