RightFax 8.5 Fax Board Guide 7
Chapter 1
Brooktrout Analog Fax Boards
efore installing any fax board into the RightFax server, you must first configure the board to
operate correctly and without hardware conflicts. If you are installing multiple fax boards of the
same or different types, watch for special notes specific to such instances. Be sure to record the I/
O addresses, DMA channels, and interrupts selected for each installed fax board; you may need this
information when configuring the fax boards in RightFax.
Warning Static discharge can severely damage your fax board. Exposing your fax board to static electricity
will void all warranties on the board. Always use caution when handling fax boards.
Installing Brooktrout TR1034 Series Analog Fax Boards
The Brooktrout TR1034 series of analog fax boards supports the v.34 fax standard, which allows fax
transmission at up to 33.6 kBPS. Instructions in this section apply to all supported Brooktrout
TR1034 analog fax boards unless otherwise noted. (If you are installing Brooktrout TR1034 series
digital fax boards, see Supported Brooktrout TR1034 Series Digital Fax Boards on page 17.)
The following table lists all of the Brooktrout TR1034 series analog fax boards supported by
RightFax.
In Brooktrouts naming scheme, TR1034 is the board model, P stands for PCI, followed by the
number of channels, and then L for the loop-start phone line interface.
Setting the module number
Each installed Brooktrout TR1034 board must be assigned a unique module number. The module
number is set using a rotary switch located on the fax board. Refer to your Brooktrout
documentation for the location of the rotary switch on your particular fax board model.
Warning Do not use a pencil or any other object that conducts electricity to move the rotary switch on the
Brooktrout TR1034 board. Using graphite and other electrically conductive materials may cause severe
damage to the board.
The module number must be unique for each Brooktrout TR1034 fax board installed in a single
computer (i.e., you cannot have two TR1034 boards in the same computer with the same module
number setting). Module numbers do not need to be sequential. Also, do not set the module number
on any Brooktrout TR1034 board to 0 or 1 (these values are reserved by Brooktrout for diagnostic
purposes.)
Make a note of the module numbers you assign to each installed TR1034 fax board. You will need to
enter this information when configuring the RightFax software to communicate with the boards.
B
Table 1A Supported Brooktrout TR1034 Series Analog Fax Boards
Board model Description
TR1034-P2L Two loop-start channel PCI analog fax board.
TR1034-P4L Four loop-start channel PCI analog fax board.