4 Integration Technical Note
©June 2003 Ericsson Enterprise AB MITEL D/82 Station Set Emulation
EN/LZT 108 6655 R1A
Critical Application Considerations
Known limitations or conditions within the telephone system and OneBox that
affect the integration performance are listed here. General recommendations are
provided when ways to avoid these limitations exist.
The Dialogic Configuration Manager defaults the PBX switch type as
Norstar. The correct PBX switch type, MITEL_DNIC_M430 must be
selected prior to starting the Dialogic service.
The Dialogic D/82 board is polarity sensitive. The Dialogic service may
fail to initialize the ports if the polarity of the PBX connection is reversed.
Terminate all station wiring as shown in the section, “Installing the Dialogic
D/82 Physical Interface” of this document.
The Lines tab must have the correct extension numbers specified in each
line.
Station numbers cannot use 0 as the leading digit. Non-numeric DTMF
tones cannot be used as any character in a station number. The maximum
length of a station number is ten digits.
Some MITEL telephone systems have automatic canceling of MWI on a
regular basis, which means that the telephone system may turn off MWI at
station sets before subscribers have called into their mailboxes and listened
to their messages.
OneBox cannot prevent the telephone system from turning off MWI, nor
can it determine when this happens. Enabling Refresh MWI at Daily
Maintenance on the Messaging tab can help compensate for this
functionality, which may be disabled on some systems. Switch specific
information is listed in this document.
Subscribers can turn on MWI at other stations and turn off their own
MWI. These features cannot be disabled.
Normal MWI set commands take between 4 and 8 seconds per station.
Additional Considerations for SX-200D G1005
with F03.9 or Higher
MWI is cleared from a subscriber telephone when it is used to call the port
or hunt group (OneBox) that set the light, even if the user does not log on
to his mailbox. MWI is also cleared when a subscriber connects via
transferred call to the port or hunt group (OneBox) that set the light. You
can compensate for this problem by changing the parameter, Preference
for Refreshing MWIs, in the Advanced Message Waiting settings of the
Integrations options dialog box.