Dialogic DSI SPCI Network Interface Boards Especificaciones Pagina 53

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 125
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 52
Dialogic
®
DSI SS7HD Network Interface Boards Programmer's Manual Issue 11
53
4.2 General Configuration Messages
General configuration messages are typically issued by the s7_mgt protocol
configuration utility, in which case they need not, and should not, be generated by any
user application software.
If the user elects not to use the s7_mgt protocol configuration utility, it is necessary
for the application to build and send messages that:
configure the ssd module
reset each board
configure each board
optionally configure additional routes
The messages in the general configuration category include:
SSD_MSG_RESET - SSD Reset Request
SSD_MSG_RST_BOARD - Board Reset Request
SSD_MSG_BOARD_INFO - Board Information Request
MGT_MSG_CONFIG0 - Board Configuration Request
MGT_MSG_L1_CONFIG - Layer 1 Configuration Request
MGT_MSG_L1_END - Layer 1 Configuration End
MGT_MSG_NTP_CONFIG - Network Time Configuration
Vista de pagina 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 124 125

Comentarios a estos manuales

Sin comentarios