1000 and 2000 Media Gateway Series User’s Guide
Parameter Reference
3.19.1.9 Call Progress Filter Debounce
Description: Specifies the debounce time in milliseconds for the Call Progress Tone Detector. This
value defines the minimum time that a call progress signal must be present before the detector is
triggered.
Allowed Values: 100 to 32768 milliseconds
Default Value = 100 milliseconds
INI File Parameter Name = cpFilterDebounce
Note: Unit requires a restart if this parameter value is changed.
3.19.1.10 Call Progress Filter Percent (DMG1000 Only)
Description: Specifies the percent ratio between tone power and total power for the Call Progress
Tone Detector. Call progress tone signals whose power is a smaller percentage of total power than
this value will be ignored.
Allowed Values: 25 to 87%
Default Value = 45%
INI File Parameter Name = cpFilterPercent
Note: Unit requires a restart if this parameter value is changed.
3.19.1.11 Call Progress Filter Low Cutoff (DMG1000 Only)
Description: Specifies the low cut-off frequency for the Call Progress Tone Detector. Call progress
signals below this frequency will be ignored.
Allowed Values: 250 Hz to 1000 Hz
Default Value = 300 Hz
INI File Parameter Name = cpFilterLowCuttoff
Note: Unit requires a restart if this parameter value is changed.